A ____ is a large single panel, frame, or assembly of panels with front- or rear-mounted switches, protective devices (overcurrent, etc.) , buses, and, usually, instruments.


A) panelboard
B) switchboard
C) circuit cabinet
D) panel cabinet

E) A) and D)
F) None of the above

Correct Answer

verifed

verified

The connection between the grounded circuit conductor (neutral) and the equipment grounding conductor at the service is the ____.


A) main switching lead
B) main bonding jumper
C) central lead
D) transverse bridge

E) A) and B)
F) B) and C)

Correct Answer

verifed

verified

All mechanical elements used to terminate a grounding electrode conductor or bonding jumper to a grounding electrode shall be ____.


A) painted
B) waterproof
C) accessible
D) lubricated

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

C

All panelboards shall have a rating not less than the ____ required for the load calculated in accordance with Part III, IV, or V of Article 220.


A) minimum feeder capacity
B) maximum feeder capacity
C) 50% of maximum feeder capacity
D) 50% of minimum feeder capacity

E) None of the above
F) A) and D)

Correct Answer

verifed

verified

The alternating current phase arrangement on 3-phase busses are ____ from front to back, top to bottom, or left to right, as viewed from the front of the switchboard, switchgear, or panelboard.


A) A, B, C
B) C, B, A
C) 1, 2, 3
D) 3, 2, 1

E) C) and D)
F) A) and C)

Correct Answer

verifed

verified

A(n) ____ minimum vertical clearance is required above finished grade for sidewalks, or from any platform or projection from which overhead conductors (of 150 volts, or less, to ground) might be reached.


A) 9-ft (2.7-m)
B) 10-ft (3.0-m)
C) 11-ft (3.3-m)
D) 12-ft (3.7-m)

E) C) and D)
F) A) and B)

Correct Answer

verifed

verified

One access means to a working space is permitted where the location provides ____.


A) a continuous and unobstructed exit
B) adequate sprinkler coverage
C) balcony exits
D) adequate overhead clearance

E) None of the above
F) A) and B)

Correct Answer

verifed

verified

A structural ceiling may not ____.


A) contain any wiring
B) contain any lighting
C) be a suspended or drop type
D) contain ductwork

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

C

According to the NEC , live parts of electric equipment operating at 50 to 1000 volts, nominal, shall be guarded against ____ by approved enclosures.


A) water damage
B) overvoltage
C) accidental contact
D) phase transformations

E) B) and C)
F) None of the above

Correct Answer

verifed

verified

C

Premises wiring (system) is defined as ____, including power, lighting, control, and signal circuit wiring together with all their associated hardware, fittings, and wiring devices, both permanently and temporarily installed.


A) interior and exterior wiring
B) interior wiring
C) exterior wiring
D) main service wiring

E) A) and C)
F) None of the above

Correct Answer

verifed

verified

Equipment rated ____ amperes (or more) and over 6 ft (1.8 m) wide requires an entrance to and egress from the required working space at least 24 in.(610 mm) wide and 6½ ft (2.0 m) high at each end of the working space.


A) 700
B) 1000
C) 1100
D) 1200

E) B) and D)
F) C) and D)

Correct Answer

verifed

verified

Overcurrent protection for transformers over ____ volts, nominal, is required.


A) 300
B) 500
C) 600
D) 1000

E) None of the above
F) A) and D)

Correct Answer

verifed

verified

Ground-fault protection that functions to open the service disconnect will afford no protection from faults on the ____ of the protective element.


A) circuit side
B) panel box side
C) underside
D) line side

E) B) and C)
F) A) and D)

Correct Answer

verifed

verified

A system that supplies a ____ and is derived from a transformer rated no more than 1000 volt-amperes does not require a grounding electrode conductor.


A) Class A, EE, AE circuit
B) main branch circuit
C) secondary circuit
D) Class 1, 2, or 3 circuit

E) A) and B)
F) None of the above

Correct Answer

verifed

verified

Where rear access is required to work on nonelectrical parts at the back of enclosed equipment, a minimum working space of ____ horizontally is required.


A) 20 in.(508 mm)
B) 30 in.(762 mm)
C) 36 in.(914 mm)
D) 40 in.(1 m)

E) All of the above
F) A) and B)

Correct Answer

verifed

verified

Where ungrounded conductors are increased in size for any reason other than as required in 310.15(B) or 310.15(C) , wire-type equipment grounding conductors (where installed) shall be increased in size ____, according to the circular mil area of the ungrounded conductors.


A) proportionately
B) inversely
C) directly
D) indirectly

E) B) and D)
F) B) and C)

Correct Answer

verifed

verified

Live generator parts operating at more than ____ volts ac to ground shall not be exposed to accidental contact by unqualified persons.


A) 25
B) 50
C) 75
D) 100

E) B) and C)
F) All of the above

Correct Answer

verifed

verified

The maximum rating for overcurrent protection on a primary unit is ____.


A) 125%
B) 250%
C) 300%
D) 350%

E) B) and D)
F) B) and C)

Correct Answer

verifed

verified

The ____ phase must be that phase having the higher voltage to ground on 3-phase, 4-wire, delta-connected systems.


A) A
B) B
C) C
D) D

E) A) and D)
F) C) and D)

Correct Answer

verifed

verified

Vertical wiring clearances apply to ____.


A) commercial services
B) residential services
C) all electrical feeder and service installations
D) dwellings over six stories

E) None of the above
F) C) and D)

Correct Answer

verifed

verified