What wire and cable options do you have for combating excessive neutral current?

Correct Answer

verifed

verified

At least one major manufacturer of Type ...

View Answer

On a 3-phase, 4-wire, wye system, reduction is allowed for nonlinear loads.


A) no
B) 10 percent
C) 50 percent
D) 75 percent

E) C) and D)
F) All of the above

Correct Answer

verifed

verified

To determine a reasonable minimum size for a neutral conductor, two types of loads must be considered- .


A) fuses and circuit breakers
B) series and parallel
C) linear and nonlinear
D) motors and hermetic units

E) B) and D)
F) B) and C)

Correct Answer

verifed

verified

C

NEC 310.10(H) sets forth the requirements for installing conductors.These requirements are intended to ensure the conductors will share the current equally to prevent overloading individual conductors.


A) phase
B) neutral
C) parallel
D) circuit

E) A) and D)
F) A) and C)

Correct Answer

verifed

verified

The ampacity is the allowable ampacity multiplied by the factor.


A) grounding
B) EMT
C) overcurrent
D) derating

E) C) and D)
F) None of the above

Correct Answer

verifed

verified

To get accurate current readings where harmonics are involved, ammeters referred to as " " must be used.


A) neutral
B) clamp-on
C) average-reading
D) true rms

E) A) and B)
F) B) and D)

Correct Answer

verifed

verified

What are the requirements for installing parallel conductors?

Correct Answer

verifed

verified

NEC 310.10(H) sets forth the requirement...

View Answer

Currents of the 3rd harmonic and odd multiples of the 3rd harmonic (9th, 15th, 21st, etc.) add together in the common neutral conductor of a 3-phase system, instead of canceling each other.These odd multiples are referred to as ____.


A) triplens
B) doublens
C) triple harmonies
D) all harmonics

E) A) and C)
F) None of the above

Correct Answer

verifed

verified

In the United States, Hz is standard or the fundamental frequency.


A) 30
B) 50
C) 60
D) 90

E) All of the above
F) A) and D)

Correct Answer

verifed

verified

For installations where the nonlinear load is huge, most consulting engineers will specify -rated transformers.


A) D
B) K
C) T
D) Y

E) A) and D)
F) B) and D)

Correct Answer

verifed

verified

When sizing feeder conductors, noncoincident loads (loads unlikely to be operated simultaneously such as the air-conditioning and the heating) need be included.


A) all of the
B) the average of the
C) only the larger of any
D) only the smaller of any

E) A) and D)
F) A) and B)

Correct Answer

verifed

verified

Often the load is such that parallel conductors should be considered.This usually occurs with loads over amperes.


A) 100
B) 400
C) 900
D) 1600

E) None of the above
F) A) and C)

Correct Answer

verifed

verified

are multiples of a fundamental frequency.


A) Overcurrents
B) Linear loads
C) Standing waves
D) Harmonics

E) A) and B)
F) C) and D)

Correct Answer

verifed

verified

If the selected OCPD has a rating greater than 100-amperes, the conductors to be installed shall be selected from either the 75 degrees Celsius or degrees Celsius column of NEC Table 310.15(B) (16) .


A) 85
B) 90
C) 100
D) 110

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

B

wire is seldom used in branch circuits, but because of weight and cost factors, it is frequently selected for feeders and services.


A) Platinum
B) Aluminum
C) Copper
D) Tungsten

E) All of the above
F) None of the above

Correct Answer

verifed

verified

What are the three conditions of failure that may occur with a 3-phase, 4-wire wye system?

Correct Answer

verifed

verified

Three conditions of failure may occur wi...

View Answer

What can you do to determine the root cause of voltage drop problems?

Correct Answer

verifed

verified

If you experience voltage drop problems,...

View Answer

If the ampacity of a feeder does not match a standard OCPD rating, then be used.


A) the next higher standard rating may
B) the next lower standard rating may
C) a custom rating may
D) a custom rating must

E) None of the above
F) All of the above

Correct Answer

verifed

verified

What three circuit parameters must be known before feeder component selection can begin?

Correct Answer

verifed

verified

Before the selection process can begin, ...

View Answer

Feeders are the part of the electrical system that connects the branch-circuit to the electrical service equipment.


A) motors
B) busbars
C) raceways
D) panelboards

E) C) and D)
F) None of the above

Correct Answer

verifed

verified

D

Showing 1 - 20 of 20

Related Exams

Show Answer