Filters
Question type

Study Flashcards

When kilovoltage is increased with no other changes in technical factors, fewer scattered photons will result.

A) True
B) False

Correct Answer

verifed

verified

When more photons are absorbed photoelectrically, the resulting radiograph has


A) greater image distortion.
B) less image distortion.
C) greater radiographic image density.
D) less radiographic image density.

E) A) and B)
F) C) and D)

Correct Answer

verifed

verified

Penumbra is a geometric unsharpness around the periphery of an image.

A) True
B) False

Correct Answer

verifed

verified

The ____ the atomic number of the irradiated material, the ____ the number of photoelectric absorption interactions will be, and the ____ the scatter produced.


A) higher; lower; less
B) higher; higher; less
C) lower; higher; more
D) lower; lower; less

E) B) and C)
F) A) and C)

Correct Answer

verifed

verified

The principal factors that affect the amount of scatter produced are mAs and the type of irradiated material.

A) True
B) False

Correct Answer

verifed

verified

The diameter of the lower rim of a cone is 5 inches.The bottom of the cone is placed at a distance of 15 inches from the focal spot.What will be the size of the projected image at a 40-inch SID?

Correct Answer

verifed

verified

As the volume of irradiated tissue ____, the amount of scatter produced ____.


A) increases; increases
B) increases; decreases
C) decreases; increases
D) decreases; decreases

E) A) and C)
F) C) and D)

Correct Answer

verifed

verified

All of the following are considered beam-restricting devices EXCEPT


A) aperture diaphragm.
B) beam filter.
C) positive beam limitation (PBL) device.
D) collimator.

E) C) and D)
F) B) and D)

Correct Answer

verifed

verified

As the kilovoltage increases, the percentage of photons that undergo a ____ interaction will decrease.


A) photoelectric
B) coherent
C) Compton
D) characteristic

E) A) and D)
F) All of the above

Correct Answer

verifed

verified

Bone absorbs more radiation and produces more scatter than soft tissue.

A) True
B) False

Correct Answer

verifed

verified

Cones and cylinders would be commonly employed for the following examinations EXCEPT


A) orbits.
B) L5-S1 spot.
C) skull.
D) AP thoracic spine.

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

As the kilovoltage increases, the percentage of x-rays that undergo ____ interactions will increase.


A) photoelectric
B) coherent
C) Compton
D) bremsstrahlung

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

Collimators that offer positive beam limitation (PBL) are very popular with technologists for a variety of reasons.Even though the federal requirement for PBL has been repealed, their popularity has continued and most department managers consider PBL as a "standard equipment" feature.PBL is electronically and mechanically highly engineered technology and subject to abuse by the inattentive and unprofessional radiographer.In the event of a PBL failure during an examination, what circumstances will be evident to the radiographer and what can he/she do to overcome the PBL error and continue with the procedure.

Correct Answer

verifed

verified

Malfunctioning PBL will not put the coll...

View Answer

A radiographer can best reduce the amount of scatter radiation from reaching the receptor by


A) collimating.
B) beam restriction.
C) utilizing a grid.
D) all of the above

E) None of the above
F) C) and D)

Correct Answer

verifed

verified

The volume of the irradiated tissue increases as


A) field size and patient thickness increase.
B) patient density increases.
C) patient orientation to the beam changes.
D) tissue composition increases.

E) None of the above
F) C) and D)

Correct Answer

verifed

verified

The collimation assembly of a radiographic unit


A) employs an upper and lower set of shutter blades.
B) allows the radiographer to adjust the field size in a circular dimension.
C) removes the mirror assembly for exposures.
D) all of the above

E) B) and D)
F) All of the above

Correct Answer

verifed

verified

A radiographer can best minimize the amount of scatter radiation reaching the image receptor by restricting the beam.

A) True
B) False

Correct Answer

verifed

verified

Automatic collimators are known as positive beam limitation (PBL) devices.

A) True
B) False

Correct Answer

verifed

verified

PBLs may also filter the x-ray beam.

A) True
B) False

Correct Answer

verifed

verified

A factor that affects the amount of scatter produced is


A) the irradiated material.
B) milliamperage.
C) time.
D) anode composition.

E) A) and C)
F) C) and D)

Correct Answer

verifed

verified

Showing 21 - 40 of 40

Related Exams

Show Answer